Mydax recirculating liquid chillers: About us, News, Frequently Asked Questions, Contact usTECHNICAL SERVICE SUPPORT for Mydax Chillers: Service-Warranty Options, Technical InformationAPPLICATIONS for Mydax Chillers: Pharmaceutical, Semiconductor, Aerospace, Automotive, Medical, Laser, Industrial, Biotech, Cryogenic. Prototype, Custom, OEM.Mydax PRODUCTS Chiller:  Very Low Temperature, Wide Temperature, Outdoor Air Cooled, Air Cooled, Water Cooled, Liquid to Liquid or Air Heat Exchanger, Precision Air Conditioner, Custom, Deionization Chelating FiltersSALES Mydax chillers: Design your Chiller, Computer Control, Engineering, Request a Quote
 
home | email 
Products
VLH Wide Temp
Outdoor Rated
Air-Cooled
Water-Cooled
Heat Exchangers
Extreme Custom
Multi-Channel
Filters

 

Mydax Air Cooled Chiller Cooler Heater Systems

MYDAX AIR COOLED CHILLER / COOLER / HEATER PRODUCTS:

Air-cooled chillers are required when no source of water is available for cooling the condenser. These units use fans to dissipate the heat removed by the refrigeration system.

When cooling requirements begin to exceed 24,000 Btu/Hr (2 ton), the heat being dissipated into a room becomes a concern. At that point we generally suggest either a water-cooled chiller or an outdoor air-cooled chiller.

Mydax Air-Cooled chillers are most often recommended when one or more of the following are required:
Mydax
Precision temperature stability
Mydax
Mydax
Multi Channel Systems for smaller footprint and economical solution for multiple cooling loop applications!
Mydax
Special fluid handling (materials, pumps, filtration)
Mydax
High reliability
Mydax
Both heating and cooling

This product is available in the following configurations:
  • Multi-Loop: 1, 2, 3 or more independent channels
Special Heat Transfer Fluid (HTF) could be:
  • Galden and H-Galden by Solvay Solexis (Ausimont)
  • Fluorinert and Novec fluids by 3M
  • Deionized Water, specify conductivity|resistivity
  • Deuterium Oxide
  • International Space Station Fluid (ISS)
Please fill out a Request For Quote Form or email: sales@mydax.com
 
 
 
 

In the Chart below, click on any of the models to see a summary of the specifications. From there, you'll be able to download the corresponding PDF datasheet to a new window.
Please Note: These are example systems that can be customized to meet your specific needs.


 
  Mydax Air Cooled Chiller Products 1M2A 1M6A 2M8A 2H12A-SS 1M12A 1M75A 1M90A  
 
 
 

AIR-COOLED SERIES - PRODUCT SUMMARY:

1M2A Specs :
Temperature Range
+10°C to +20°C
Number of Channels
1
Cooling Capacity
586 Watts at +10°C
Heating Capacity
-
Temperature Stability
± 0.4°C or better
Fluid (HTF)
Deuterium Oxide / Methanol
Reservoir Volume
1 Gallon
Pump: Flow at Pressure
1 GPM at 120 PSI
Input Power
208/240VAC, 60Hz, 1ph, 20 Amp
Configuration
Indoor, Air-cooled
1M6A Specs :
Temperature Range
0°C to +60°C
Number of Channels
1
Cooling Capacity
1.8 KW at +10°C (60Hz)
1.5 KW at +10°C (50Hz)
Heating Capacity
1.5 KW
Fluid (HTF)
Fluorinert FC-3283
Temperature Stability
± 0.5°C or better
Reservoir Volume
2.5 Gallons
Pump: Flow at Pressure
2.5 GPM at 50 PSI
Input Power
200/240VAC, 50/60Hz, 1ph, 25 Amp
Configuration
Indoor, Air-cooled
2M8A Specs :
Temperature Range
+15°C to +35°C
Number of Channels
2
Cooling Capacity
885 Watts @ +28°C (Loop 1)
1465 Watts @ +28°C (Loop 1)
Heating Capacity
2 KW each Loop
Temperature Stability
± 1.0 °C or better
Fluid (HTF)
Water / Ethylene Glycol
Reservoir Volume
5 Gallons (Loop 1 Closed Loop)
None (Loop 2 Open Loop)
Pump: Flow at Pressure
4 GPM at 30 PSI, 2 GPM at 60 PSI, each
Input Power
208/230VAC, 60Hz, 3ph, 40 Amp
Configuration
Indoor, Air-cooled
2H12A-SS Specs :
Temperature Range
-20°C to +80°C (Loop 1)
+10°C to +80°C (Loop 2)
Number of Channels
2
Cooling Capacity
750 Watts at -20°C (Loop 1)
2250 Watts at +20°C (Loop 2)
Heating Capacity
2.2 KW each loop
Temperature Stability
± 0.25°C or better
Fluid (HTF)
DI Water / Ethylene Glycol
Reservoir Volume, each
4 Gallons
Pump: Flow at Pressure
3 GPM at 50 PSI
Input Power
208/230VAC, 60Hz, 3ph, 30 Amp
Configuration
Indoor, Air-cooled
1M12A Specs :
Temperature Range
0°C to +60°C
Number of Channels
1
Cooling Capacity
3.6 KW at +10°C (60Hz)
3.0 KW at +10°C (50Hz)
Heating Capacity
3.0 KW
Temperature Stability
± 0.5°C or better
Fluid (HTF)
Fluorinert FC-3283
Reservoir Volume
5 Gallons
Pump: Flow at Pressure
4 GPM at 50 PSI
Input Power
200/240VAC, 50/60Hz, 1ph, 40 Amp
Configuration
Indoor, Air-cooled
1M75A Specs :
Temperature Range
+15°C to +40°C
Number of Channels
1
Cooling Capacity
22 KW +21°C fluid
Heating Capacity
10 KW
Temperature Stability
± 0.5°C or better
Fluid (HTF)
Water
Reservoir Volume
10 Gallons
Pump: Flow at Pressure
10 GPM at 25 PSI
Input Power
440/480VAC, 60 Hz, 3ph, 50 amp
Configuration
Indoor, Air-cooled
1M90A Specs :
Temperature Range
+0°C to +20°C
Number of Channels
1
Cooling Capacity
26 KW at +5°C
Heating Capacity
-
Temperature Stability
± 0.5°C or better
Fluid (HTF)
Ethylene Glycol / Water
Reservoir Volume
59 Gallons
Pump: Flow at Pressure
30 GPM at 30 PSI
Input Power
440/480VAC, 60Hz, 3ph, 30 Amp
Configuration
Indoor, Air-cooled
 
 