Our slogan "Need a better chiller?" describes
our mission to provide the industry with a chiller, different
than all the others, better than the rest.
It's
why Mydax was started in 1986 and it's still true today. Come
to Mydax first, when you don't have time to do it twice!
Mydax is the
only recirculating liquid chiller manufacturer in the
world offering patented
proportional refrigeration control. Proportional control,
combined with an embedded
computer operating with proprietary
software, empowers the Mydax chiller to achieve important
customer benefits.
US Patents: |
4,742,689 |
4,959,972 |
4,934,155 |
6,793,007B1 |
6,827,135 |
Mydax, Inc. is a privately held company,
located in the beautiful Sierra Nevada foothills, just
outside of Sacramento, California.
Click
here for more contact information.

The MYDAX ADVANTAGE
is as simple
as 1,2,3...
[Printable
version available in PDF]
-
Proportional Control Provides Low Thermal Stress Refrigeration
Your number one advantage when you buy a Mydax chiller
is our use of a low thermal stress refrigeration system.
The
U.S. Patent Office granted Mydax its first patent on this
technology in 1988; since that time our unique design has
proven to
be a highly reliable chiller. Mydax chillers are used in
every demanding industry from Medical and Pharmaceutical
Sciences, to Semiconductor Fab equipment, to Lasers and
Space to name a few.
If you are not satisfied with the shutdowns and service
problems that go hand-in-hand with conventional chillers,
you will appreciate the benefits of Mydax's technology.
Most of the wear and breakdowns on a chiller are caused
by the
temperature cycling of the refrigeration circuit's plumbing
and components. This cycling, long associated with conventional
chillers, is eliminated in the Mydax design!
The Mydax Proportional Refrigeration technology smoothly
adjusts the flow of refrigerant along the compressor's
power curve, based on the amount of cooling required.
If the unit
is in a high power slew, refrigerant gas will be smoothly
turned on for maximum flow to the evaporator. When little
cooling power is required, gas flow to the evaporator is
reduced and only a minimum flow of refrigerant is modulated
smoothly into the bypass heat exchanger. Using this method
of proportional flow control, Mydax's microprocessor
eases the thermal stress on components.
-
Construction Technique and Choice of Components is Vital
Mydax Chillers are built with Pride. Our employees strive
for the quality that our customers have
come to depend on
from Mydax. Each chiller is carefully constructed
by knowledgeable builders, all units are then thoroughly
inspected and tested to ensure they meet design specifications.
• Steel tube frames are completely welded eliminating
the weaknesses found in typical bolted-together sheet metal
systems.
• All permanent copper fittings in the refrigeration
circuit are brazed; this eliminates leak-prone flare fittings
and low-temperature solder joints. All circuits are sniffed
before initial operation with a helium leak detector to
locate even the smallest leak.
• Components are chosen from only the most reliable
manufacturers. Since pump seals are a primary reliability
concern, we'll make a recommendation based upon the type
of fluid and temperatures used. Our compressors are selected
from either Danfoss/Maneurop, Copeland, or Bitzer
-- the most reliable compressors in the industry.
• Units built for operating over extreme temperature ranges
are carefully insulated with appropriate materials to reduce
losses and ice build up; all seams are taped or glued.
• The chiller construction and ratings are in
accordance with ARI 590-92. Our chillers are designed
in compliance
with UL-471, UL-1995, NFPA-79 Industrial Machinery safety
design standards and the National Electrical Code NFPA-70.
All models
may be submitted for CE and
UL/ETL markings.
-
Diagnostics and Self Protection Safeguards Your Chiller
Our embedded microprocessor operates the chiller in much
the same way as the electronic ignition on a car; it is
constantly adjusting the operation and controls for optimal
performance.
If operations become too close to predefined limits, the
controller can send an alarm to the user to prevent a shut-down.
This
is what we call "self-diagnostics". During operation,
parameters used to control the system are available on
the Test Panel displays; if a fault occurs, these numbers
alone
can often be enough to assess the problem and suggest possible
corrective action.
Alarms can be programmed to provide early-warning detection
of possible failures so corrective action can be taken before
a fault occurs.
• A Condenser Hot alarm indicates the air flow
through an air-cooled condenser has become
blocked by dirt or snow. This
can be very helpful between scheduled periodic maintenance.
• With the built-in flowmeter, an alarm can provide
warning if the recirculation loop becomes restricted
or a fluid line ruptures.
• A level sensor in the fluid reservoir can warn that
the fluid level in the tank becomes low. Servicing this "Fill
Tank" message can avoid costly system shut-downs
if the fluid were to drain to the lower tank-empty
sensor.
• An over-temperature alarm will warn if the fluid
is beyond the operating range.
Protection devices are wired into a Safety Interlock loop
which will stop the chiller in the event of a serious
problem. These are set in accordance with safety and fire
protection
codes to prevent a catastrophic failure from being
hazardous or damaging other components. Each chiller is
equipped with
a minimum of a refrigerant high pressure switch and
a tank-empty switch. All heated units have an over-temperature
switch.
An RS-232C port comes standard on all chillers for remote
control and monitoring. A Windows ™ based application
program is available from Mydax for remotely controlling
your chiller or logging the performance data into a
file.
[Printable
version available in PDF]
That's what we do,
Mydax
|